logo
Casa > produtos >
Localizador de falhas de cabo
>
Xhhg521A Digital Cable Fault Sheath Prelocator for Underground Cable Fault Distance Measure

Xhhg521A Digital Cable Fault Sheath Prelocator for Underground Cable Fault Distance Measure

Detalhes do produto:
Lugar de origem: CHINA
Marca: XZH Test
Certificação: CE/ISO
Número do modelo: XHGG521A
Informações detalhadas
Lugar de origem:
CHINA
Marca:
XZH Test
Certificação:
CE/ISO
Número do modelo:
XHGG521A
Destacar:

High Light

Destacar:

digital cable fault locator

,

underground cable fault detector

,

cable sheath prelocator tool

Trading Information
Quantidade de ordem mínima:
1Unit
Detalhes da embalagem:
Caixa de madeira
Tempo de entrega:
5-8 dias de trabalho
Termos de pagamento:
T/T.
Habilidade da fonte:
2000 unidade/ano
Descrição do produto



XHGG521A

Model NO.
XHHG521A
Test Mode
Saved Test
Test Region
Forming Cable
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
No-Load Voltage
0~4000V
Short Circuit Current
≥40mA
Positioning Accuracy
± (0.2% * L ± 1) Meters
Weight
5.5kg
Working Power Supply
AC 220V+/-10% 50Hz
Transport Package
Wooden
Specification
5.5kg
Trademark
XZH TEST
Origin
China Xi'an
HS Code
854320100
Production Capacity
100 Pieces /Year

Product Description

Product Description

Introduction
The cable outer sheath fault tester XHHG521A is designed based on the MURRAY bridge principle and can be used to locate the breakdown points of various wires and cables and the defect points that have no breakdown but low insulation resistance values.

The device utilizes an electric voltage regulator in combination with an R-type transformer to create a high-voltage constant current source. The voltage can be adjusted upward or downward via button operation. It features a no-load voltage of 7,500V and a short - circuit current of 100mA. A high - sensitivity amplifier and galvanometer are employed to indicate balance. Together with a proportional potentiometer, it constitutes a balanced bridge, and the entire setup is situated at a high potential. The measurement cable is a specially designed two - core high - voltage rubber cable. The four - terminal resistance measurement method is applied to eliminate errors resulting from lead resistance. The entire panel remains at a low potential. One - touch operation allows for entering the cable length and automatically calculating the fault distance. The high - voltage source and bridge are integrated into a portable protective box. Thus, the device boasts high voltage, light weight, easy operation and safe use.

High voltage bridges are particularly suitable for
1. The high-resistance breakdown point of the cable after laying, especially the linear high-resistance breakdown point that is difficult to burn into low resistance, such as the linear high-resistance breakdown of the cable intermediate joint.
2. Flashover type breakdown point. After breakdown, the constant current source can maintain the arc, a stable current flows through the bridge, and the bridge has sufficient sensitivity.
3. Defects that have not yet broken down but have low resistance, such as insulation defects found with a megohmmeter that have low cable resistance but do not break down under the operating voltage.

Xhhg521A Digital Cable Fault Sheath Prelocator for Underground Cable Fault Distance Measure 0

Product Features

  1. Output voltage is adjustable;
  2. Has high accuracy and stability;
  3. Adopt high-sensitivity amplifier and galvanometer to indicate balance;
  4. Zero protection;
  5. Automatically test fault points, but retain manual testing functions;
  6. Compared with the wave reflection method, the bridge balance method has no blind area and is used to determine the breakdown point of short cables and near the ends.

Product Parameters

No load voltage ≥7500V
Short circuit current ≥100mA (when adjusting balance, it is recommended to set it at 5~40mA);
Positioning accuracy ±(0.2%·L±1)m
Weight 25kg
Power supply  AC 220V (±10%), 50Hz±1Hz; 8.4V built-in battery.